Wall MountedMulti-Split SystemAir Conditioning/Heat PumpDMC24DB-1DMH24DB-1Before servicing the unit, read the“safety precautions” in this manual.Only

Página 2 - TABLE OF CONTENTS

10 Multi type Air ConditionerDimensionsDimensionsIndoor UnitSplit Type IndoorInstallation plateDHWW mm(in) 895(35.2)H mm(in) 282(11.1)D mm(in) 165(6.5

Página 3 - Combination table

Service Manual 11Outdoor UnitWDL1L2L4L3HL7L5L6W mm(in) 870(34.3)H mm(in) 800(31.5)D mm(in) 320(12.6)L1 mm(in) 370(14.6)L2 mm(in) 25(1.0)L3 mm(in) 775

Página 4 - Safety Precautions

12 Multi type Air ConditionerProduct SpecificationsProduct Specifications DMC24DB-123,600/24,000 11,800/12,000 208/230V--2.4(0.085) 1.2(0.042) at 230V

Página 5

Service Manual 13Product SpecificationsDMH24DB-123,600/24,000 11,800/12,000 208/230V23,600/24,000 11,800/12,0002.4(0.085) 1.2(0.042) at 230V1Ø, 208/2

Página 6

14 Multi type Air ConditionerInstallationInstallationType "A" screw and plastic anchorType "B" screwRemote Control HolderInstallat

Página 7 - ■ Installation

Service Manual 15InstallationIndoor unit1. Do not have any heat or steam near the unit.2. Select a place where there are no obstacles in frontof the

Página 8 - ■ Operational

16 Multi type Air ConditionerInstallationMulti Piping TypePiping length and elevation24k 30m(100ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft)Capacity(B

Página 9 - • They may burn or explode

Service Manual 17InstallationThe wall you select should be strong and solid enough toprevent vibration1. Mount the installation plate on the wall wit

Página 10 - Dimensions

18 Multi type Air ConditionerFlaring Work and Connection of PipingFlaring workMain cause for gas leakage is due to defect in flaring work. Carry out c

Página 11 - Outdoor Unit

Service Manual 19Flaring Work and Connection of PipingCheck1. Compare the flared work with the figure by.2. If a flared section is defective, cut it

Página 12 - Product Specifications

2 Multi type Air ConditionerMulti type Air Conditioner Service ManualTABLE OF CONTENTSCombination table...

Página 13 - DMH24DB-1

20 Multi type Air ConditionerFlaring Work and Connection of Piping4. Indoor unit installationHook the indoor unit onto the upper portion of the instal

Página 14 - Installation

Service Manual 21Flaring Work and Connection of Piping1. Route the indoor tubing and the drain hose to the requiredpiping hole position.2. Insert the

Página 15 - Select the best location

22 Multi type Air ConditionerWrap the insulation material around the connecting por-tion.1. Overlap the connection pipe heat insulation and the indoor

Página 16 - Piping length and elevation

Service Manual 23Flaring Work and Connection of PipingRemove the battery cover from the remote con-troller.• Slide the cover according to the arrow d

Página 17 - Service Manual 17

24 Multi type Air ConditionerOutdoorAlign the center of the pipings and sufficiently tighten the flarenut by hand.Finally, tighten the flare nut with

Página 18 - Point down

Service Manual 25Flaring Work and Connection of PipingConnect the cable to the indoor unit by connecting the wires to the terminals on the control bo

Página 19 - Connecting the Piping

26 Multi type Air ConditionerConnect the cable to the Outdoor unit.1. Remove the cover control from the unit by loosening thescrew.Connect the wires t

Página 20 - 20 Multi type Air Conditioner

Service Manual 27Connecting the Cable between Indoor Unit and Outdoor Unit(1) Remove two-caps on the conduit panel.(2) Make a hole appropriate for th

Página 21 - For left rear piping

28 Multi type Air ConditionerConnect the cable to the indoor unitCAUTION: Provide a circuit breaker between power source and the unit as shownbelow.Ai

Página 22 - 22 Multi type Air Conditioner

Service Manual 29Checking the Drainage, Forming the Pipings and Long Pipe SettingChecking the drainageTo check the drainage.1. Pour a glass of water

Página 23 - Service Manual 23

Service Manual 3Operation1 Unit2 UnitCombination of Indoor Unit(kBtu/h)CoolingEach CapacityUnit-A Unit-BUNIT-A(Btu/h) UNIT-B(Btu/h)Total Btu/h kWUNIT

Página 24 - 24 Multi type Air Conditioner

30 Multi type Air ConditionerChecking the Drainage, Forming the Pipings and Long Pipe SettingForming the pipingForm the piping by wrapping the con-nec

Página 25 - Conditioner

Service Manual 31Air Purging and EvacuationAir and moisture remaining in the refrigerant system have undesirable effects as indicated below.1. Pressu

Página 26 - Outdoor unit

32 Multi type Air ConditionerChecking the Drainage, Forming the Pipings and Long Pipe Setting1. Connect the charge hose end described in the preceding

Página 27 - Strand wire

Service Manual 33Charging Each outdoor unit is factory charged (nameplate charge) for the evaporator as well as a 7.5m(25ft) line set for each indoo

Página 28 - Connecting cable

34 Multi type Air Conditioner1. Check that all tubing and wiring have been properly con-nected.2. Check that the gas and liquid side service valves ar

Página 29 - Checking the drainage

Service Manual 35Operation 1. MAIN UNIT FUNCTION • DISPLAYOperation Indicator• On while in appliance operation, off while in appliance pause• Flashin

Página 30 - Forming the piping

4 Multi type Air ConditionerSafety Precautions Safety PrecautionsTo prevent injury to the user or other people and property damage, the following in

Página 31 - Air Purging and Evacuation

Service Manual 5Safety Precautions Do not install, remove, or re-install the unit by yourself(customer).• There is risk of fire, electric shock,expl

Página 32 - Evacuation

6 Multi type Air ConditionerSafety Precautions Do not open the inlet grill of the productduring operation. (Do not touch the elec-trostatic filter,

Página 33 - Charging

Service Manual 7Safety Precautions When the product is not to be used for a long time,disconnect the power by turning off the breaker.• There is ris

Página 34 - Tubing connection

8 Multi type Air ConditionerSafety Precautions Do not expose the skin direct-ly to cool air for long periodsof time. (Don't sit in the draft.)•

Página 35 - Operation

Service Manual 9Safety Precautions Do not recharge or disassemble the batteries.Do not dispose of batteries in a fire.• They may burn or explode.If